Governance, risk, continuity / A complete guide for SMEs
The architecture
of defense.
How a small or medium enterprise builds its cybersecurity, from the first board meeting to the annual review. Seventeen phases, the people who carry them out, the documents that prove them and the laws that require them, told through a simulated company.
- 17phases of the programme, from mandate to review
- 24professional roles described, internal or external
- 54documents that make up the evidence file
- 12months of simulated calendar for a medium enterprise
The map and the vocabulary
A company can have antivirus, backups and a support contract without knowing how secure it is. The difference between buying tools and building a defense is a method: knowing what matters, measuring the risks, acting, verifying and, above all, being able to prove it.
Anyone approaching the subject immediately hits a language problem. Audit, assessment, penetration test, BIA are used as synonyms, and that confusion produces wrong contracts and disappointed expectations: a penetration test is ordered in the hope of a complete picture of security, and what comes back is a list of exploitable weaknesses on a narrow perimeter. It is worth pinning down the words before anything else.
- Assessment
- Measures a condition against a reference: "where are we?". It can be internal, informal, repeated often.
- Gap analysis
- An assessment focused on the distance between the current situation and a precise target, for example the measures required by NIS2.
- Audit
- An independent, evidence-based check that stated requirements are met. It does not ask "are we secure?", it asks "what you say you do, do you do it, and can you prove it?".
- Vulnerability assessment
- A systematic, largely automated search for known technical weaknesses on authorized systems.
- Penetration test
- A manual, controlled test, within a written mandate, of how exploitable those weaknesses really are and how far they would take an attacker.
- Business Impact Analysis
- Estimates the consequences of each process stopping, over time. It does not talk about threats: it talks about how much standing still costs.
- Risk assessment
- Evaluates uncertain scenarios, combining probability and impact, to decide where to invest.
- BCP and DRP
- The continuity plan says how the company keeps working, even in a reduced way; the disaster recovery plan says how systems and data are rebuilt.
The second orientation tool is a map. The NIST Cybersecurity Framework 2.0 organizes security into six functions: Govern sets strategy, expectations and policy; Identify understands current risks; Protect applies the safeguards; Detect finds and analyses possible attacks; Respond acts on incidents; Recover restores operations and assets. [26] The Italian National Framework for Cybersecurity and Data Protection, 2025 edition, has aligned its core with the CSF 2.0, and the baseline measures that the National Cybersecurity Agency (ACN) asks of NIS entities use that same coding (GV, ID, PR, DE, RS, RC). [50] [5] Learning this grid, then, is not an academic exercise: it is the language in which you speak to the authority.
- Board mandate
- Regulatory framing
- Roles and responsibilities
- Inventory
- Business Impact Analysis
- Risk and treatment
- Gap analysis
- VA and penetration test
- Remediation and roadmap
- Technical controls
- Secure development and products
- Suppliers and supply chain
- Monitoring and SOC
- Incident response
- Continuity and DR
- Training and culture
- Internal audit and review
↺ The review (phase 17) reopens the mandate (phase 1): the programme is a cycle, not a project with an end date.
The case study
ALFA S.r.l. is an invented company, built to make the steps concrete. It designs and builds automatic packaging machines, has 85 employees, two sites (offices and plant), an ERP system, Microsoft 365, a customer web portal written in React and Node.js, a production line with connected PLCs, and an external IT supplier that manages servers and network. The machines it sells have an operator panel and a remote-assistance module over the Internet. Every number, name and result attributed to ALFA is a teaching example, not a measured datum.
The board's mandate
It all starts in the boardroom, not in the server room. Without a formal decision on objectives, budget and responsibilities, every later activity remains an IT initiative that the first production emergency can suspend.
For an entity in scope of NIS2 this is not a matter of style. The Italian transposition decree establishes that the management and governing bodies approve the way risk-management measures are implemented, oversee their implementation, are liable for breaches and must follow training in information security (art. 23 of Legislative Decree 138/2024, transposing art. 20 of the directive). [2] [1] Security thus becomes a matter of company governance, like the balance sheet or workplace safety.
Even outside NIS2 the board has good reasons to take on the mandate. The GDPR asks the controller to put adequate measures in place and to be able to demonstrate it; Legislative Decree 231/2001 lists cybercrimes among the offences that can generate the entity's liability (art. 24-bis), with penalties toughened by Law 90/2024; more structured customers, themselves subject to obligations, pass requirements down into supply contracts. [10] [16]
What the board actually decides
The mandate is not a generic resolution "in favour of security". It must answer questions only those who govern the company can close: which services cannot stop, how much residual risk one is willing to accept (so-called risk appetite), who coordinates the programme and with what authority, what resources are allocated for the first year, how often management wants to be informed. For the first months the priority is to fund knowledge — inventory, BIA, risk and gap analysis — because without that data any budget estimate for countermeasures would be a guess.
ALFA · week 1
The board resolves to launch the "Security Programme 2026-2027", appoints the IT manager as interim coordinator reporting directly to the CEO, hires an external consultant as a virtual CISO for twelve months and asks for a first report within ninety days covering inventory, regulatory applicability and main risks. The directors enrol in the first training module.
- Resolution of the governing body with objectives, initial perimeter, budget and appointment of the coordinator.
- First risk-appetite statement, even qualitative, to be refined after the BIA.
- Reporting calendar to management (at least quarterly in the first year).
- Rules for urgent action: who can stop a system, who authorizes an unplanned expense.
- Planning of directors' training.
- Documents
- Board resolution or minutes; Project Charter; appointment of the coordinator; first Risk Appetite Statement.
- Who
- Governing body (decides), CEO (sponsor), security coordinator or CISO (proposes and executes).
- References
- Legislative Decree 138/2024 art. 23; GDPR arts. 5(2) and 24; NIST CSF 2.0, Govern function.
Which rules actually apply
The first mistake is wanting to "apply all of NIS2" before knowing whether the company is a target of it. The second is forgetting that a company excluded from NIS2 can have important obligations for privacy, labour, products and contracts.
The applicability analysis is done by concrete activities, not by acronyms. Start from the economic-activity code, the size, the products sold and the customers served, and for each rule write down why it applies or why not. That reasoning is already a document: if one day an authority or a customer asks, the answer is in the register, with the date and signature of whoever assessed it.
The NIS2 test, step by step
- Does the activity fall within a sector of the annexes? Annex I lists highly critical sectors (energy, transport, health, digital infrastructure…), Annex II other critical sectors, including the manufacturing of computers and electronics, electrical equipment, machinery and equipment, motor vehicles and other transport equipment.ALFA builds machinery: yes, Annex II.
- Does the company exceed the small-enterprise ceilings? The regime applies to medium and large enterprises per Recommendation 2003/361/EC: in short, from 50 employees or over 10 million in turnover and annual balance sheet. There are exceptions that bring in even small entities (for example certain digital-service providers or entities unique in their market).ALFA has 85 employees: it is a medium enterprise.
- Essential or important? Annex II enterprises, and Annex I ones that do not exceed the medium-enterprise ceilings, are generally important entities; the essential ones are usually the large Annex I entities and those designated.ALFA is an important entity.
- Registration. The entity registers on the ACN digital platform from 1 January to 28 February each year, indicating a point of contact; from 15 April to 31 May it updates the information (IP addresses, domains, deputy point of contact). [2] [3]ALFA checks that it registered and received the notice of inclusion in the list.
- Obligations and deadlines. The deadlines set by the ACN to adopt the baseline security measures and to notify significant incidents run from the date of the inclusion notice. For entities included in 2026 a calendar was indicated: CSIRT contact (Computer Security Incident Response Team, the national team that receives and coordinates incident notifications) by 31 December 2026, incident notification from 1 January 2027 and baseline measures by 31 July 2027. [6]Every entity must recompute its own deadlines from the date of its own notice.
The baseline measures are not left to interpretation. With Determination no. 379907 of December 2025, applicable from 15 January 2026 and replacing the earlier no. 164179 of April 2025, the ACN set, for important entities, a set of 37 measures and 87 requirements (43 measures and 116 requirements for essential ones), organized according to the National Framework. [4] [5] The ten families of measures in art. 24 of the decree, which echo art. 21 of the directive, are the thread of this whole guide: risk-analysis policies, incident handling, business continuity and backup, supply-chain security, security in the development and maintenance of systems with vulnerability management, assessment of the effectiveness of measures, cyber hygiene and training, cryptography, personnel security with access control and asset management, multi-factor authentication and secure communications. [2]
Penalties, without scaremongering
For important entities the decree provides penalties up to 7 million euro or 1.4% of worldwide annual turnover, whichever is higher; for essential ones up to 10 million or 2% (art. 38). [2] These are maximums, graded by severity and circumstances. The practical message is another: the same rule that provides penalties asks directors to oversee, so the absence of a documented programme weighs first of all on those who govern.
Not everything is measured in euro. The ACN can make public the details of established violations and of the responsible entities: the reputational damage, towards customers and partners, can exceed the financial penalty. And an entity that is not compliant with its security obligations risks being excluded from public-procurement tenders, where NIS2 conformity is increasingly a requirement: an indirect cost that hits precisely those who work with the public administration.
Not only NIS2: the complete map
| Rule | When it comes into play | Operational effect | ALFA |
|---|---|---|---|
| NIS2Dir. (EU) 2022/2555 · Leg. Decree 138/2024 | Annex sectors, above the small-enterprise ceilings, or designated entities. | Governance, ACN baseline measures, incident notification at 24 h / 72 h / 1 month, annual registration. | Yes, important entity. |
| GDPRReg. (EU) 2016/679 | Any processing of personal data, from employees to customers. | Security appropriate to the risk (art. 32), records of processing, contracts with processors, breach notification within 72 hours, DPIA in high-risk cases. | Yes, as for every company. |
| Workers' StatuteLaw 300/1970, art. 4 | Tools from which remote monitoring of workers can also result. | Union agreement or Labour Inspectorate authorization for some monitoring tools, notice to employees. | Yes: affects logs, SOC, video surveillance. |
| Leg. Decree 231/2001art. 24-bis, amended by Law 90/2024 | Cybercrimes committed in the interest or to the advantage of the entity. | The 231 organizational model, if adopted, must include safeguards on cybercrimes. | To integrate into the 231 model. |
| Cyber Resilience ActReg. (EU) 2024/2847 | Manufacturers of products with digital elements placed on the EU market. | Reporting of exploited vulnerabilities and severe incidents from 11 September 2026; full requirements from 11 December 2027. [19] | Yes, for machines with software and remote assistance. |
| Machinery RegulationReg. (EU) 2023/1230 | Machine builders. | From 20 January 2027, requirements for protection against corruption of systems and reliability of control systems. [25] | Yes. |
| AI ActReg. (EU) 2024/1689, amended by Reg. (EU) 2026/1744 | Providers and deployers of AI systems, by risk level. | Staff AI literacy; high-risk obligations from 2 December 2027 (Annex III) and 2 August 2028 (Annex I). [21] [22] | Yes as a deployer of AI assistants; to be assessed for any AI functions in the machines. |
| Italian AI lawLaw 132/2025 | Use of AI in the employment relationship. | Notice to workers on the use of AI systems. [23] | Yes, if AI touches personnel management. |
| DORAReg. (EU) 2022/2554 | Financial entities, from 17 January 2025. | Indirect: contractual clauses for those supplying ICT services to banks and insurers. [24] | No. |
| CERDir. (EU) 2022/2557 · Leg. Decree 134/2024 | Only entities identified as critical by the authorities. | Overall resilience, including physical. [54] | No. |
Before reading the table, one distinction explains why some rules carry a double label. A European directive — like NIS2, Dir. (EU) 2022/2555 — sets the objectives but must be transposed by a national law: in Italy it is Legislative Decree 138/2024 that translates its obligations, and that is where the concrete penalties and deadlines live. A regulation — like the GDPR or the Cyber Resilience Act — instead applies directly in every member state, with no transposition needed. This is why NIS2 comes with a decree, while the GDPR does not.
Two clarifications avoid the most frequent misunderstandings. The first concerns proposals: in January 2026 the European Commission presented targeted amendments to NIS2 together with the new Cybersecurity Act, and the so-called Digital Omnibus proposes a single point for notifications; as of October 2026 these are still proposals under discussion and do not change the obligations in force. [8] The second concerns Implementing Regulation (EU) 2024/2690, often cited as "the NIS2 technical measures": it applies to digital-service providers such as cloud, data centres, managed services and DNS, not to a machine builder, for which the ACN specifications apply. [9]
- Collect the company registration extract, ATECO codes, size data, list of products, markets and regulated customers.
- Run the NIS2 test and verify registration, point of contact and notices received from the ACN.
- For each rule, write applicability and reasoning; for doubtful cases seek legal advice.
- Turn every obligation into a row of the register: requirement, owner, control, evidence, deadline.
- Plan a review at least annually and at every relevant change (new product, acquisition, new regulated customer).
- Documents
- Legal register of obligations; reasoned applicability matrix; compliance calendar; ACN registration receipts.
- Who
- Legal or compliance (leads), GRC, DPO or privacy contact, CISO, NIS point of contact, management (approves).
- References
- Leg. Decree 138/2024 arts. 3, 7, 23-25, 38; ACN determinations; GDPR; Law 300/1970 art. 4; Leg. Decree 231/2001; CRA; AI Act.
The people: roles and functions
A security programme is made of decisions, and every decision needs a first and last name. In an SME many functions are performed by the same person or by a supplier: that is fine, as long as it is clear who does what and as long as whoever checks is not the same person who executes.
The descriptions that follow are functions, not jobs to be created. For each one we give the task, the reason it is needed, the typical skills and the most realistic form for a company of about a hundred people. The reference professional profiles are those of the European skills framework ENISA (ECSF) and the US NICE Framework, useful for writing job descriptions and selecting consultants, not for imposing an org chart. [51] [52]
Who decides and who answers
Governing body
Internal · mandatoryNIS2 art. 23- What it does
- Approves strategy, policy, budget and residual risk; oversees implementation; receives reports; follows training.
- Why needed
- The law assigns directors approval, supervision and liability. No consultant can take those on in their place.
- Documents
- Resolutions, review minutes, formal acceptance of residual risks.
CISO or security manager
Internal or virtualECSF: Chief Information Security Officer- What it does
- Coordinates the programme, proposes priorities, manages the risk register, prepares reports to management, chairs the security committee.
- Why needed
- Someone must hold together technology, risk and rules and speak the language of the business.
- Skills
- Risk management, security architecture, regulation, communication to the top. Common certifications: CISSP, CISM, ISO/IEC 27001 Lead Implementer.
- In the SME
- Often an external part-time virtual CISO, supported by an internal contact.
NIS point of contact and deputy
Internal · mandatory for NIS entitiesLeg. Decree 138/2024 art. 7- What it does
- Manages registration and annual updates on the ACN platform, receives the authority's notices, tracks deadlines.
- Why needed
- It is the Agency's formal counterpart: an unread notice is a missed deadline.
- In the SME
- A manager or the compliance officer, with a designated deputy.
CSIRT contact
Internal or externalACN determinations- What it does
- Handles incident notifications to CSIRT Italia and the technical liaison during the event.
- Why needed
- The 24- and 72-hour deadlines require a person already identified, reachable and trained.
- In the SME
- Usually the same as the incident manager or the security-service supplier, with a backup.
Security committee
Coordination body- What it does
- Brings together monthly CISO, IT, production, legal, HR and a management representative for progress, exceptions and new risks.
- Why needed
- Prevents security decisions being taken in isolation and without those who will bear their effects.
Who assures the rules
Legal and compliance
Internal or external firm- What it does
- Analyses the applicability of the rules, drafts contractual clauses with suppliers, assesses notification obligations during an incident, manages relations with the authorities.
- Skills
- Technology law, data protection, labour law, corporate liability.
DPO or privacy contact
Mandatory only in some casesGDPR arts. 37-39- What it does
- Monitors GDPR compliance, advises on impact assessments (DPIA), cooperates with the Garante (the Italian supervisory authority).
- When mandatory
- For public authorities, for those who systematically monitor people on a large scale or process special categories of data on a large scale. A manufacturer like ALFA generally does not fall within this and appoints an internal privacy contact; if it does appoint a DPO, they must remain autonomous and free of conflicts of interest. [10]
GRC analyst and risk manager
Internal or consultantECSF: Cybersecurity Risk Manager- What it does
- Maintains registers of obligations, risks and exceptions; prepares the gap analysis; collects evidence; supports the audit.
- Why needed
- Turns rules into controls and controls into documented proof.
231 supervisory body
If the company has a 231 model- What it does
- Oversees the effectiveness of the organizational model, including safeguards against cybercrimes, and receives information flows from the CISO.
Auditor
Independent of the audited functionsECSF: Cybersecurity Auditor- What it does
- Verifies, with criteria, samples and evidence, that the stated controls exist and work. Does not design or run the controls it checks.
- Skills
- Audit techniques per ISO 19011, knowledge of ISO/IEC 27001 and the NIS2 framework. Common certifications: ISO/IEC 27001 Lead Auditor, CISA.
Who builds and runs the systems
IT manager and system administrators
Internal and supplier- What it does
- Manages servers, workstations, identities, Microsoft 365, backups, patches and configurations; maintains the technical inventory.
- Watch out
- Administrative accounts are attackers' favourite target: they must be separated from everyday-use ones and protected with strong authentication.
Network and cloud engineer
Often external- What it does
- Designs segmentation, firewalls, VPN, Wi-Fi and cloud configurations; documents network flows.
OT and production manager
Internal- What it does
- Knows PLCs, SCADA systems, operator panels and physical-safety constraints; authorizes any intervention on the line.
- Why needed
- In industrial systems an aggressive scan can stop a machine or create a hazard for people. NIST SP 800-82 and the IEC 62443 series address exactly these differences. [34] [56]
Security engineer and architect
Internal or consultantECSF: Cybersecurity Architect / Implementer- What it does
- Designs and implements the countermeasures: hardening, multi-factor authentication, EDR, encryption, email protection, vulnerability management.
Developer and DevSecOps
Internal- What it does
- Integrates security into the development lifecycle of the web portal and the machine software: requirements, code review, dependency analysis, pipeline protection, secrets management.
Who verifies, watches and intervenes
Vulnerability analyst
Internal or service- What it does
- Runs periodic scans, removes false positives, sets priorities combining technical severity, real exploitation and asset importance.
Penetration tester and ethical hacker
External, with written mandateECSF: Penetration Tester- What it does
- Simulates an attacker on an authorized perimeter to demonstrate which weaknesses are exploitable and with what consequences.
- Skills
- Offensive techniques, methodologies such as NIST SP 800-115, OWASP for applications, writing understandable reports. Common certifications: OSCP, PNPT, eCPPT. [32]
SOC analyst
Almost always an external service (MSSP)ECSF: Cyber Incident Responder- What it does
- Watches alerts from endpoints, identities, network and cloud; distinguishes false positives from incidents; starts the response procedure.
- In the SME
- An internal 24/7 SOC requires several shifts of analysts: for a company of 85 people the managed service is the normal choice.
Incident manager
Internal, with deputy- What it does
- During an incident coordinates people and decisions, keeps the event log, asks management for the choices that are theirs, activates the CSIRT contact and legal.
Forensic analyst (DFIR)
External, under contract before the emergencyECSF: Digital Forensics Investigator- What it does
- Collects and preserves evidence, reconstructs how the attack happened, what was touched and whether the attacker is still present.
- Why under contract beforehand
- Negotiating an engagement during an attack wastes precious hours.
Who assures continuity and the people
Business continuity manager (BCM)
Internal, often part time- What it does
- Runs the BIA, writes the continuity and recovery plans, organizes the exercises, compares real times with targets.
Process owners
Internal- What it does
- Administration, production, sales and logistics state the impact of outages, approve RTO and RPO, test recovery from the point of view of real work.
Human resources and communication
Internal- What it does
- HR manages joiners, leavers and role changes (with access revocation), training, and relations with union representatives on art. 4 of the Statute. Communication prepares messages to employees, customers and press in case of crisis.
Procurement and supplier management
Internal- What it does
- Inserts security requirements into specifications and contracts, collects supplier assessments, tracks deadlines.
The RACI matrix
For each activity the RACI matrix indicates who performs it (Responsible), who answers for and approves it (Accountable, a single person), who is to be consulted (Consulted) and who informed (Informed). It is the document that settles in advance the most costly question during an emergency: "who decides?".
| Activity | Board | CISO | IT | Legal | Process owner | MSSP |
|---|---|---|---|---|---|---|
| Approve the security policy | A | R | C | C | I | I |
| Accept a high residual risk | A | R | C | C | C | – |
| Set the ERP's RTO and RPO | I | C | C | – | A/R | – |
| Apply critical patches | – | A | R | – | C | I |
| Classify an incident | I | A | C | C | I | R |
| Notify CSIRT Italia | I | A | C | R | – | C |
| Test a restore | I | C | R | – | A | – |
- Formally appoint roles and deputies; for NIS entities, the point of contact, its deputy and the CSIRT contact.
- Draft the general security policy and the main thematic policies, approved by management.
- Build the RACI matrix for all the activities in this guide.
- Separate those who execute from those who verify; document the exceptions unavoidable in an SME.
- Set up the security committee and the decisions register.
- Documents
- Security org chart; appointment letters; RACI matrix; general policy and policy register; decisions register.
- Who
- Management (approves), CISO (drafts), HR and legal (consulted).
- References
- Leg. Decree 138/2024 arts. 7 and 23; ISO/IEC 27001 clause 5; ENISA ECSF; NIST NICE.
Inventory of assets, data and suppliers
You cannot protect what you do not know you have. The inventory is the least spectacular phase and the one all the others depend on: the BIA, the risk, the scans and even the notification of an incident, which requires knowing quickly which systems are involved.
A good inventory is not a spreadsheet filled in once. It is an up-to-date representation of five different things: devices (servers, workstations, smartphones, network gear, PLCs); software and services (installed applications, SaaS, cloud services); identities (personal, administrative, service accounts, API keys); data (where it resides, who processes it, how sensitive it is); suppliers with access or a role in the processes. It is no coincidence that the first two CIS controls, in the IG1 basic-hygiene group, are precisely the inventory of enterprise assets and of software. [39]
The most effective technique is to compare different sources: purchase records, the endpoint-protection console, the identity directory, SaaS invoices, authorized network scans, interviews with departments. Discrepancies are valuable information. A laptop that appears in the invoices but not in the antivirus console is an unprotected device; a SaaS subscription paid with a department's card is a data processing no one has assessed.
ALFA · weeks 3-6
Comparing sources surfaces three surprises: an old test server still powered on and reachable from the office network, eight former-employee accounts still active on Microsoft 365, a 4G modem installed years earlier by a supplier for remote assistance to a line machine, never documented. None is an incident, but each is a door.
Alongside the lists two diagrams are needed: the network diagram, which shows zones, links and remote-access points, and the data-flow diagram, which follows personal and industrial data from entry to storage. The second also feeds the records of processing required by the GDPR, which the exemption for enterprises under 250 employees does not cover when processing is not occasional, such as payroll, or concerns special categories, such as employees' health data. [11]
- Collect the existing lists and compare them; run an authorized network discovery (passive or agreed on the OT network).
- Assign each asset an owner, a criticality and a classification of the data it processes.
- Census identities and privileges: who is administrator of what, which service accounts exist.
- List the suppliers with access to systems or data, with contact and contract.
- Define how the inventory stays up to date: every purchase, joiner or decommission goes through a procedure.
- Documents
- Asset register; software and SaaS inventory; register of privileged identities; network diagram; data-flow diagram; GDPR records of processing; supplier register.
- Who
- IT and IT supplier (R), OT manager, privacy contact, process owners (C), CISO (A).
- References
- Leg. Decree 138/2024 art. 24 (asset management); GDPR art. 30; CIS Controls 1 and 2; NIST CSF 2.0 ID.AM.
Business Impact Analysis
The BIA does not talk about hackers. It asks those who work: if this process stopped, what would happen after an hour, after a day, after a week? The answers set how quickly the technology will have to restart, and therefore how much will have to be spent.
NIST SP 800-34 describes the BIA in three steps: determine the processes and their recovery criticality, identify the resources they depend on, set the recovery priorities. [29] The result is expressed with three quantities worth distinguishing.
- MTD · maximum tolerable downtime
- The total outage management is willing to accept before the damage becomes unacceptable.
- RTO · recovery time objective
- The maximum time a system can remain unavailable; it must be shorter than the MTD, to leave room for checks.
- RPO · recovery point objective
- The point in time, before the interruption, to which data must be recoverable: in practice, how much data one accepts to lose.
- Degraded mode
- How the process can keep going without the system: paper forms, telephone, a manual order. Often the cheapest continuity resource.
An RPO of one hour means that backups, or replication, must capture data at least every hour; an RTO of four hours means that people, procedures and infrastructure must allow the service to be rebuilt in that time. These are technical commitments with a cost, which is why they are signed by those who benefit from them: the process owner.
| Process | Systems it depends on | Impact of the outage | MTD | RTO | RPO |
|---|---|---|---|---|---|
| Production | PLC, MES, ERP (work orders), OT network | Line stopped, delivery penalties after 48 h | 24 h | 8 h | 4 h |
| Shipping and invoicing | ERP, email, e-invoicing | Collection delays, tax obligations | 72 h | 24 h | 1 h |
| Customer support | Web portal, remote assistance, telephone | Customers' machines stopped, reputational damage | 24 h | 12 h | 24 h |
| Payroll | External service of the labour consultant | Delay in wages at month end | 5 days | 3 days | 24 h |
The table surfaces the real information of the BIA: the dependencies. Production depends on the ERP, the ERP on Microsoft 365 identities, everything on the network and DNS. Restoring a service means restoring first what it rests on, and this order will become the sequence of the disaster recovery plan.
- Interview the process owners with a uniform questionnaire on impacts over time (economic, legal, contractual, people's safety, reputation).
- Map the dependencies on systems, people, suppliers and sites.
- Propose MTD, RTO and RPO and have them approved by those who run the process and by management.
- Identify the already-feasible degraded modes.
- Review the BIA at least yearly and at every organizational change.
- Documents
- Completed BIA questionnaires; BIA report; dependency matrix; approved RTO/RPO table.
- Who
- BCM manager (R), process owners (A for their own values), IT (C), management (approves the whole).
- References
- Leg. Decree 138/2024 art. 24 (business continuity); NIST SP 800-34 Rev. 1; ISO 22301.
Risk assessment and treatment
If the BIA says how much an outage hurts, the risk assessment says how plausible it is to happen and why. Together they allow spending the budget where it most reduces expected damage, instead of where the vendor is most convincing.
According to NIST SP 800-30, risk is a function of the probability that a threat event occurs and its potential adverse impact; the factors to consider are the threat, the vulnerability, the impact, the probability and the predisposing conditions. [28] Translated into an example: the threat is a ransomware group, the vulnerability is a VPN access protected by a password alone, the predisposing condition is the flat network that does not separate offices and production, the impact is told by the BIA, the probability is estimated by experts informed by data on real threats.
For real threats, institutional sources help avoid chasing fashions. The ENISA Threat Landscape 2026 report, covering 2025, indicates ransomware as the highest-impact threat, phishing as the dominant social-engineering technique and a growing role of software supply-chain attacks. [46] The MITRE ATT&CK catalogue describes tactics and techniques observed in attacks and lets you turn a scenario into a concrete sequence of steps to prevent or detect. [47]
For each risk, management chooses one of four paths: mitigate with controls, avoid by giving up the activity that generates it, transfer part of the economic consequences (contracts, cyber insurance), accept the residual risk with a signature and a review date. Transfer does not transfer responsibility: a policy can reimburse costs, not replace the notification obligations or the duty to oversee.
| ID and scenario | R1 · A ransomware affiliate uses stolen credentials to enter via the VPN, moves through the flat network and encrypts servers and ERP. |
|---|---|
| Assets and processes | VPN, Active Directory, ERP, file server · production and invoicing. |
| Existing controls | Traditional antivirus, daily backup to a NAS on the network. |
| Inherent assessment | Probability 4 · Impact 5 · Score 20 (critical). |
| Treatment | Mitigate: phishing-resistant MFA on the VPN, managed EDR, office-OT segmentation, immutable offline backup, restore testing. |
| Expected residual risk | Probability 2 · Impact 4 · Score 8 (medium), to be confirmed after the tests. |
| Owner and deadline | CISO · by the fourth month · quarterly review. |
- Write and get approved a methodology: scales, acceptance criteria, frequency.
- Build the scenarios from critical assets, realistic threats and known vulnerabilities.
- Assess probability and impact, documenting the assumptions and the uncertainty.
- Decide the treatment of each risk, with owner and deadline; obtain formal acceptance of the residuals.
- Review after incidents, changes and results of technical checks.
- Documents
- Risk-management methodology; risk register; treatment plan; residual-risk acceptance statements.
- Who
- Risk manager or CISO (R), process owners and IT (C), management (A for acceptance and budget).
- References
- Leg. Decree 138/2024 art. 24(a); GDPR art. 32; NIST SP 800-30 Rev. 1; ISO/IEC 27005:2022.
Gap analysis and assessment
The gap analysis compares what the company does with what it should do. The value is not in the final score, but in the reasoned list of distances, each with the proof that documents it.
The first step is choosing the reference. For a NIS entity the mandatory reference is the ACN baseline measures; for everyone, the CSF 2.0 offers the mechanism of profiles: the current profile describes the outcomes the organization is achieving, the target profile the ones it has chosen and prioritized. [26] The NIST quick-start guide for small businesses is designed precisely for those starting with modest or absent security plans. [27] Those aiming at certification add ISO/IEC 27001, whose Annex A gathers 93 controls; certification is not required by NIS2, but a well-built management system makes it easier to demonstrate compliance. [36]
The method is the same as an audit, applied in a spirit of self-diagnosis: for each requirement you collect evidence (a configuration, a log, minutes), not statements. "We have MFA" is not evidence; the export of the conditional-access policy with the list of excluded accounts is. The distinction avoids the most common trap of self-assessment, optimism.
| Area | Situation found | Evidence | Level |
|---|---|---|---|
| Policy and risk | No approved policy; risk never assessed before the programme. | Absence of minutes | Absent |
| Incident handling | No written procedure; the IT supplier is called "when needed". | IT contract | Absent |
| Continuity and backup | Daily backup to a NAS reachable from the network; a full restore never tested. | Backup-software log | Partial |
| Supply chain | Contracts without security clauses; the supplier's remote access always on. | Contracts, VPN configuration | Partial |
| Vulnerabilities | Automatic patches on workstations; servers and firewalls updated irregularly. | Patch inventory report | Partial |
| Training | No training in the last three years, not even for administrators. | HR register | Absent |
| Access and assets | Former-employee accounts active; administrators with a single account for daily use. | Directory export | Partial |
| Strong authentication | MFA on Microsoft 365 for users, not on the VPN nor on administrative accounts. | Access policies | Partial |
- Choose the reference (ACN measures, CSF 2.0, ISO/IEC 27001) and build a checklist.
- For each requirement collect evidence through interviews, documents, configurations and samples.
- Assign an implementation level and describe the distance in understandable terms.
- Link each gap to the risk it generates and the rule that requires it.
- Present to management the current profile and the proposed target profile.
- Documents
- Checklist; evidence register; gap-analysis report; current profile and target profile.
- Who
- GRC or consultant (R), CISO (A), control owners (C).
- References
- ACN determinations on baseline measures; NIST CSF 2.0 and SP 1300; ISO/IEC 27001 and 27002.
Vulnerability assessment and penetration test
The gap analysis looks at processes; technical checks look at systems through an attacker's eyes. They are complementary: a company can have perfect policies and an exposed server with a vulnerability known for months.
The mandate before the tools
No offensive check starts without written authorization from someone entitled to give it. This is not bureaucracy: unauthorized access to a computer system is a crime (art. 615-ter of the penal code, with penalties increased by Law 90/2024), and what distinguishes a test from an attack is precisely the documented consent of the owner. [16] The rules of engagement set the perimeter, addresses and applications included and excluded, time windows, forbidden techniques (for example denial of service), emergency contacts and rules for the data encountered. If the perimeter touches cloud or supplier services, their consent under their conditions is also needed. On the production network, passive techniques and tests on a staging environment are preferred, because industrial devices can react badly to anomalous traffic. [34]
Two different activities
The vulnerability assessment is periodic and broad: authenticated scanners compare versions and configurations with known vulnerabilities (identified by CVE codes) and assign a severity. The value is created by the analyst who removes false positives and decides the order of action. The CVSS severity, now at version 4.0, measures the base technical severity, and the specification itself asks to enrich it with threat and context metrics before using it to assess risk. [41] Two sources help understand what is really being exploited: CISA's KEV catalogue, which lists vulnerabilities with known exploitation, and FIRST's EPSS model, which estimates the probability that a vulnerability will be exploited in the next thirty days. [55] [40]
The penetration test is targeted and deep. A professional tries to chain weaknesses as an attacker would: from the web portal to a database, from a compromised mailbox to Active Directory. NIST SP 800-115 describes the phases of planning, discovery, attack and reporting; for web applications the reference is the OWASP Top 10, updated in 2025, and the verifiable requirements of OWASP ASVS 5.0. [32] [49] [48]
| Check | Question it answers | Typical frequency for an SME |
|---|---|---|
| External scan | What does the Internet see of us? | Continuous or monthly |
| Authenticated internal scan | Which systems have missing patches or weak configurations? | Monthly |
| Perimeter pentest | Can an external attacker get in? | Annual and after major changes |
| Internal pentest (assume breach) | If a PC were compromised, how far would one get? | Annual |
| Application pentest | Does the portal protect data and authorizations? | At every relevant release |
| Phishing simulation | Do people recognize and report a deception? | Quarterly, for training |
| Cloud and OT configuration review | Do the settings follow the baselines? | Annual |
A good penetration-test report has two souls: a summary for management, explaining in business language what an attacker could have obtained, and a reproducible technical part, with evidence, exploitation conditions and recommendations. A "critical" finding without this information does not allow a decision. After the fix, the retest closes the loop and becomes the evidence that the vulnerability is gone.
ALFA · month 3
The internal pentest starts from an office workstation. On the old test server the tester finds plaintext credentials of a service account with domain-admin privileges: within hours they could have controlled the whole network. The finding confirms scenario R1 of the risk register and moves segmentation and privileged-account management to the top of the roadmap. The example is didactic, but the chain (forgotten credentials, excessive privileges, flat network) is among the most described in incident-response reports.
- Draft and get signed the authorization and rules of engagement, including any suppliers.
- Start the periodic vulnerability assessment and define maximum fix times by severity.
- Commission penetration tests to professionals independent of those who run the systems.
- Prioritize by combining CVSS, KEV, EPSS and asset exposure.
- Run the retest and archive the evidence.
- Documents
- Authorization letter; rules of engagement; VA report; penetration-test report; findings register; retest report.
- Who
- Vulnerability analyst and penetration tester (R), CISO (A), IT and OT (C), management (I on the summary).
- References
- Leg. Decree 138/2024 art. 24(e) and (f); NIST SP 800-115; OWASP ASVS and Top 10; FIRST CVSS and EPSS; CISA KEV.
Remediation plan and roadmap
At this point the company has far more to fix than it can do in a quarter. The remediation plan turns the list into a sustainable sequence, starting from what reduces the most risk with the least effort.
The priority rule combines three criteria: how much risk the action reduces, how much it costs in time and money, which actions unblock others. Some controls have such a favourable benefit-to-effort ratio that they deserve immediate execution: their effectiveness against the most common attacks is documented by the main institutional guides for small businesses, from ENISA to CISA. [45] [42]
- First 30 daysDisable orphan accounts, MFA on VPN and admins, an offline backup copy, power off the test server, remove the 4G modem.
- Within 90 daysManaged EDR on all endpoints, separate administrative accounts, patch exposed systems, first incident-response procedure.
- Within 6 monthsOffice and OT segmentation, immutable backup, supplier remote access on request, training for all staff.
- Within 12 monthsManaged SOC with centralized logs, tested BCP and DR plans, secure development of the portal, first internal audit.
Every action goes through change management: description, impact assessment, approval, execution window, rollback plan. In production this is vital: a badly configured firewall between offices and the line can stop the factory more effectively than an attack. Every item in the plan has an owner, a date, an estimated cost and a verifiable closure criterion, for example "MFA active on 100% of administrative accounts, verified by export".
When an action is not possible, for a technical or economic constraint, an exception is recorded: why, which compensating control replaces it, who approves it and until when it is valid. A PLC that does not support authentication is isolated in a dedicated segment and monitored; it is not forgotten.
- Unify findings from gap analysis, technical checks and risk into a single backlog.
- Order by risk reduced, effort and dependencies; separate immediate actions from projects.
- Estimate costs and resources; obtain budget approval.
- Execute with change management and rollback; verify closure with evidence.
- Record exceptions with compensating controls and a deadline.
- Documents
- Remediation backlog; approved roadmap; change registers; exceptions register.
- Who
- CISO (A), IT, security engineer and suppliers (R), management (approves budget and roadmap).
- References
- Leg. Decree 138/2024 art. 24; NIST CSF 2.0 target profile; ISO/IEC 27001 clause 6.1.3.
The essential technical controls
Protection is not a product but a layering: if one layer gives way, the next slows the attacker, monitoring sees them and the backup limits the damage. Here are the layers an SME cannot skip, explained by what they do.
Identity and access
Today most attacks do not "break into" a system: they come in with valid credentials. That is why identity is the new perimeter. Multi-factor authentication, explicitly required by NIS2, must be extended to email, VPN, remote access and above all administrative accounts. [2] Not all MFA is equal: according to CISA, one-time codes and push notifications remain exposed to phishing, SMS is also vulnerable to SIM swapping, while the only widely available phishing-resistant form is the one based on FIDO/WebAuthn, that is security keys and passkeys. [43] The 2025 NIST SP 800-63B-4 guidelines also dropped complexity rules and mandatory periodic password changes, preferring minimum length, checking against lists of compromised passwords and changing only upon suspected compromise. [33] The principle of least privilege completes the picture: everyone has only the access their work needs, admins use separate accounts, every departure from the company immediately revokes access.
Endpoints, servers and updates
Every device follows a reference configuration (baseline) that disables what is not needed. An EDR, that is an endpoint detection and response system, replaces the old antivirus: it does not just look for known files, it watches behaviours such as the mass encryption of documents and can isolate the machine. Patches follow maximum times proportionate to risk, with priority for Internet-exposed systems and for vulnerabilities in the KEV catalogue. [55]
Network and segmentation
A "flat" network, where every device sees all the others, lets an attacker move from any workstation to the most important server. Segmentation separates offices, servers, guests, production and supplier access, letting through only the necessary flows. For the industrial network, the zones-and-conduits model of IEC 62443 is the most widespread reference. [56]
Email and browsing
Phishing remains the main entry vector. Domain-authentication protocols (SPF, DKIM, DMARC) make it harder to send messages in the company's name; anti-spam and anti-malware filters and attachment isolation reduce what reaches users; a "report" button makes it easy to alert security.
Cryptography
Encrypting laptop disks, communications and backups is required by NIS2 as a policy and encouraged by the GDPR, which even exempts from communication to data subjects when the breached data was rendered unintelligible. [10] Passwords stored by applications must be protected with adequate cryptographic functions, as the joint ACN and Garante guidelines on password storage indicate. [17]
Backup
Against ransomware the backup is the last line of defense, provided the attacker cannot reach it. CISA recommends the 3-2-1 rule, three copies of important data on two different media types with one copy off-site, together with offline, encrypted copies and scheduled restore tests. [44] [42] In practice: an immutable or disconnected copy, backup-system credentials different from the domain ones, documented test restores.
Event logging
Without logs there is no investigation. Authentication, administration, email, VPN, firewall, EDR and cloud-service events must be collected and kept in a protected place, with synchronized clocks. Collecting logs, however, also means processing employees' data: the rules in chapter 13 must be defined before switching collection on.
- Identity: phishing-resistant MFA for admins and remote access, separate accounts, periodic privilege review.
- Endpoint: baseline, EDR, disk encryption, patch management with defined times.
- Network: segmentation, controlled remote access, protection of the perimeter and of OT devices.
- Email: SPF, DKIM, DMARC, filters, reporting procedure.
- 3-2-1 backup with an immutable copy and restore tests; centralized, protected logs.
- Documents
- Configuration baseline; access-control policy; cryptographic policy; backup policy; periodic patch and privilege reports.
- Who
- Security engineer, IT, network engineer, OT manager (R), CISO (A).
- References
- Leg. Decree 138/2024 art. 24(c), (g), (h), (i), (l); CIS Controls IG1; CISA; NIST SP 800-63B-4; IEC 62443.
Secure development and product security
ALFA does not only use software: it writes it, in the customer portal and in the machines it sells. From that moment security also concerns those outside the company, and the Cyber Resilience Act turns it into a product obligation.
The web portal
For a React and Node.js application, security is designed before writing code. The NIST SSDF framework (SP 800-218) organizes practices into four groups: prepare the organization, protect the software, produce well-protected software, respond to vulnerabilities. [35] Concretely this means defining security requirements (the ASVS offers a verifiable catalogue), threat-modelling the sensitive functions, doing code review, using static analysis (SAST) and dependency analysis (SCA), protecting the CI/CD pipeline and the secrets, and testing authorizations and sessions before every release. [48] Broken access control is first in the OWASP Top 10 2025, which now dedicates a specific category to software supply-chain failures. [49]
The machines and the Cyber Resilience Act
A machine with an operator panel and remote assistance is a product with digital elements, and whoever manufactures it and sells it under their own brand is a manufacturer under the CRA. From 11 September 2026 the manufacturer must report actively exploited vulnerabilities and severe incidents concerning its products: an early warning within 24 hours of becoming aware, a notification within 72 hours and a final report within 14 days of a corrective measure being available for vulnerabilities, or within a month of notification for severe incidents. [18] Reports go through the single platform run by ENISA, operational from 11 September 2026, and are addressed to the CSIRT of the State where the manufacturer has its main establishment. [20]
From 11 December 2027 all requirements apply: security by design, vulnerability management throughout the support period (as a rule at least five years, or the expected use life if shorter), security updates, technical documentation, software bill of materials (SBOM), conformity assessment and CE marking. [19] From 20 January 2027 the Machinery Regulation adds specific requirements for protection against corruption of systems and reliability of control systems. [25] If in future the machines integrated AI components with safety functions, the AI Act would also come into play, whose obligations for these products have been moved to 2 August 2028. [21]
What it really takes to report within 24 hours
A public address where researchers and customers can report vulnerabilities; a coordinated-disclosure policy; an up-to-date list of the components of each product version to know immediately which machines are affected; a person who knows how to use the reporting platform; an agreement with component suppliers to receive their advisories promptly.
Artificial intelligence in the office
AI assistants used by staff raise very concrete security questions: what data can be entered, who stores it, with what permissions an assistant connected to email can act. The AI Act asks providers and deployers to adopt measures to support staff AI literacy; the 2026 amendment clarified that a guaranteed level for each person is not required. [21] Italian Law 132/2025 also requires informing workers when AI is used in managing the employment relationship. [23] For applications based on language models the technical reference is the OWASP Top 10 for LLM Applications. [58]
- Adopt a secure development lifecycle with requirements, review, SAST, SCA, testing and pipeline protection.
- Generate and maintain the SBOM of the portal and the machine firmware.
- Publish a vulnerability-disclosure policy and a reporting channel.
- Prepare the CRA reporting procedure (24 h / 72 h / final report) and get onboarded to the ENISA platform.
- Plan full compliance with the CRA and the Machinery Regulation; define the support period.
- Write an AI use policy and a literacy path.
- Documents
- Secure development procedure; SBOM per version; vulnerability-disclosure policy; CRA reporting procedure; AI use policy.
- Who
- DevSecOps and developers (R), engineering and quality (C), CISO (A), legal (C).
- References
- Reg. (EU) 2024/2847 art. 14 and annexes; Reg. (EU) 2023/1230; AI Act art. 4; NIST SP 800-218; OWASP.
Suppliers and supply chain
The IT supplier with administrative access, the management software updated remotely, the labour consultant who keeps the payslips: each one extends the company's perimeter. NIS2 recognizes this explicitly and requires managing the security of relations with direct suppliers.
The decree asks to take into account the specific vulnerabilities of each direct supplier, the quality of their products and their security practices, including secure development procedures. [2] The GDPR, for its part, requires relying only on processors offering sufficient guarantees and regulating the relationship with a contract providing, among other things, documented instructions, security measures, assistance and the right to audit. [10]
The supply chain works in both directions. ALFA is a customer of its suppliers, but it is also a supplier to others: its customers, if they too are NIS entities, will ask it for questionnaires, clauses and proof. The ACN has also required NIS entities to communicate their relevant suppliers to the Agency, in the annual window between 15 April and 31 May. [7] Having one's own security file already in order thus becomes a commercial advantage too.
| Level | Criterion | Examples | What is required |
|---|---|---|---|
| Critical | Privileged access or service with no short-term alternative | Managed IT supplier, cloud ERP, MSSP | In-depth questionnaire, certifications or audit, incident-notification and audit clauses, exit plan, annual review. |
| Relevant | Processes personal or industrial data | Labour consultant, CRM, external design studio | Data-processing agreement, standard questionnaire, biennial review. |
| Ordinary | No access to systems or data | Stationery, building maintenance | General confidentiality clauses. |
For a critical supplier the clauses that matter are few and precise: an obligation to notify incidents within a term compatible with the company's NIS and GDPR deadlines, MFA and named accounts for every remote access, a right of verification, cooperation during an incident, return and deletion of data at the end of the relationship, declared sub-suppliers.
- Classify suppliers by criticality starting from the phase-4 register.
- Assess critical and relevant suppliers before engagement and periodically.
- Update contracts with security clauses and, where needed, data-processing agreements.
- Control supplier remote access: named, with MFA, activated on request, logged.
- Prepare responses to your own regulated customers' questionnaires.
- Documents
- Supplier-management policy; register with classification; questionnaires and assessments; contracts and art. 28 GDPR agreements; remote-access register.
- Who
- Procurement (R), CISO and legal (C/A), privacy contact (C).
- References
- Leg. Decree 138/2024 art. 24(d) and para. 3; GDPR art. 28; ACN determinations on relevant suppliers.
Monitoring and SOC
Sooner or later something will get past the defenses. The difference between a contained incident and a catastrophe often lies in the hours between the first signal and the first person who looks at it.
A Security Operations Center collects events in a correlation system (SIEM) or an extended detection platform (XDR), compares them with rules and anomalous behaviours, and puts in front of an analyst only what deserves attention. The real work is triage: understanding within minutes whether an alert is a false positive, an event to follow or the start of an incident. For this the SOC needs written use cases, tied to the scenarios in the risk register: VPN access from an unusual country, creation of a new domain administrator, disabling of the EDR, deletion of backups, mass encryption on a file server. Mapping these cases to MITRE ATT&CK techniques helps understand what is seen and what stays dark. [47]
For an SME the realistic form is the managed service (MDR or MSSP) active 24/7, with a contract specifying take-over times, actions allowed without authorization (for example isolating an endpoint), escalation to the internal incident manager and return of logs at the end of the relationship.
Monitoring without violating workers' rights
In Italy security monitoring meets article 4 of the Workers' Statute. Tools from which remote monitoring of employees' activity can also result may be used only for organizational and production needs, for workplace safety and for protecting company assets, and require an agreement with union representatives or, failing that, the authorization of the Labour Inspectorate; tools used to perform the job itself are excluded, and in any case workers must receive adequate information on how they are used and on the controls. [15]
The data-protection authority (the Garante) has applied these principles to email: in its June 2024 guidance document it indicates that the retention of email metadata should not, as an orientation, exceed 21 days, and that longer or generalized retention requires the guarantees of art. 4, para. 1, that is an agreement or authorization; it also considers an impact assessment necessary for log collection. [14] There is no equally specific ruling for EDR and SIEM, but the reasoning is the same and the prudent choice, to be validated with legal, is to treat the SOC project as a processing to be assessed with a DPIA, to be transparently notified and, where necessary, agreed with the representatives.
ALFA · months 6-9
Before activating the SOC service, HR and legal meet the works council, present purposes, data collected, retention times and who can access the logs, and sign an agreement. The privacy contact drafts the DPIA and updates the employee notice. The SOC starts with twelve use cases tied to risks R1-R3.
- Define the log sources and use cases starting from the risk register.
- Choose the model (internal, managed, hybrid) and contract the times and powers of the service.
- Complete the DPIA, the employee notice and, if necessary, the union agreement or Labour Inspectorate authorization before go-live.
- Set proportionate retention times and logged access to the logs.
- Periodically review false positives, use cases and coverage.
- Documents
- Logging and monitoring policy; use-case catalogue; SOC contract with SLA; DPIA; union agreement or authorization; updated notice.
- Who
- MSSP and SOC analysts (R), CISO (A), legal, HR and privacy contact (C), works council (party to the agreement).
- References
- Law 300/1970 art. 4; GDPR arts. 13 and 35; Garante, guidance on email metadata (2024); NIST CSF 2.0 DE.CM and DE.AE.
Incident response and notifications
An incident is not the moment to decide who decides. The response plan serves to make people and procedures work when email is encrypted, the management system is down and the phone will not stop ringing.
Revision 3 of the NIST SP 800-61 guide, published in April 2025, placed incident response inside overall risk management, organizing it around the CSF 2.0 functions: response is prepared by governing, inventorying and protecting, not only by reacting. [30] The ISO/IEC 27035-1:2023 standard describes the same path as preparation, detection and reporting, assessment, response and learning. [57]
What the plan contains
- Classification: criteria to distinguish event, incident and significant incident, with examples.
- Organization: incident manager and deputy, technical team, legal, communication, management; on-call numbers on paper and on an alternative channel.
- Playbooks: operational sequences for the main scenarios (ransomware, email compromise, data theft, attack on a machine in the field).
- Evidence: how to collect logs, memory and disk images without altering them, and how to document the chain of custody.
- Notifications: who assesses the obligations, by when, with which forms.
- External contacts already under contract: DFIR, legal, insurance, critical suppliers.
Three different clocks
The most common mistake is to think of a single 72-hour deadline. In reality different obligations can be triggered, with different recipients and conditions, and they must be assessed in parallel.
NIS2 · significant incident to CSIRT Italia
- 24 hEarly warning from becoming aware of the incident
- 72 hNotification with an initial assessment of severity and impact
- 1 monthFinal report from the notification
GDPR · personal-data breach to the Garante
- 72 hNotification, unless unlikely to pose a risk; beyond the term the delay must be justified
- Without delayCommunication to data subjects if the risk is high
- AlwaysInternal documentation of every breach, even if not notified
CRA · exploited vulnerability or severe product incident via the ENISA platform
- 24 hEarly warning
- 72 hNotification
- 14 d / 1 monthFinal report (from the fix for vulnerabilities, from the notification for incidents)
For the GDPR the Garante provides an online procedure and a self-assessment tool that helps understand whether notification is due; the European EDPB guidelines 9/2022 explain how to assess the risk and what to communicate. [12] [13] For NIS2 the ACN has defined the baseline categories of significant incident: for an important entity they concern the loss of confidentiality to the outside, the loss of integrity with external impact and the breach of expected service levels. [5] Regardless of the obligations, a cyber attack is a crime and filing a report with the judicial authority, through the Polizia Postale, is to be assessed with legal.
A simulation, hour by hour
| When | What happens | Who acts |
|---|---|---|
| Saturday 02:10 | The EDR detects anomalous encryption on a file server and isolates it automatically; the SOC confirms two more servers involved. | MSSP |
| 02:40 | The SOC calls the on-call incident manager; the incident log is opened. From here the deadline assessments start running. | SOC, incident manager |
| 03:30 | Containment: isolation of the server network from production, disabling the VPN, reset of administrative credentials. The line is safely stopped by the OT manager. | IT, OT, MSSP |
| 06:00 | Activation of the DFIR contract and legal; the forensic team acquires images and logs before any restore. | Incident manager, DFIR, legal |
| 09:00 | Crisis meeting with management: status, impacts on the BIA, assessment of obligations. First message to employees. | Management, CISO, communication |
| Within 24 h | Early warning to CSIRT Italia: the incident is potentially significant for service unavailability. GDPR assessment underway: searching for traces of exfiltration. | CSIRT contact, legal |
| Within 72 h | NIS2 notification with the initial assessment. DFIR finds evidence of exfiltration of employee data: notification to the Garante and assessment of communication to data subjects. | CSIRT contact, privacy contact |
| Days 2-6 | Eradication and restore from the immutable backup following the dependency order; testing by process owners; gradual restart of production. | IT, BCM, process owner |
| Within 1 month | Final report to the CSIRT; lessons-learned meeting; update of risks, controls and plan. | CISO, incident manager |
Pay the ransom?
The general advice of the No More Ransom initiative, promoted by Europol with the Dutch police and private partners, is not to pay: there is no guarantee of getting the key and payment funds new attacks. [53] The decision, which rests with management together with legal, must in any case be taken knowing that payment does not exempt from any notification obligation and that stolen data remains in the hands of whoever took it.
- Write the plan with classification, roles, on-call, alternative channels and playbooks.
- Prepare the notification forms and a matrix that, for each type of incident, indicates rules, recipients and terms.
- Contract DFIR and legal in advance; verify the cyber-insurance conditions, if any.
- Exercise the plan at least once a year (chapter 15).
- After every incident, collect the lessons learned and update risks and controls.
- Documents
- Incident-response plan; playbooks; notification matrix; incident register; GDPR breach register; notifications sent; post-incident reports.
- Who
- Incident manager (R), CISO (A), SOC, DFIR, IT, OT, legal, privacy contact, CSIRT contact, communication, management.
- References
- Leg. Decree 138/2024 art. 25; GDPR arts. 33-34; CRA art. 14; NIST SP 800-61 Rev. 3; ISO/IEC 27035.
Continuity, disaster recovery and crisis management
A successful backup does not prove the company can restart. Only a tested restore proves it, measured with a stopwatch and validated by those who actually use those systems.
Three documents, often confused, answer different questions. The crisis-management plan says who convenes the committee, how decisions are made, how to communicate with employees, customers, authorities and press. The business continuity plan (BCP) says how critical processes continue, even in degraded mode, while systems are down: orders taken by phone, shipments with paper documents, production on already-planned orders. The disaster recovery plan (DRP) describes how infrastructure, applications and data are rebuilt, in what order and with what instructions. NIS2 gathers them under the same measure, which comprises backup management, disaster recovery and crisis management. [1]
Restoring the ERP does not only mean bringing the database back online. It needs network, DNS, identities, licences, configurations, integrations with invoicing and production, and people who verify the data is correct. The restore order comes from the BIA dependency matrix; the step-by-step instructions (runbooks) must be available even if the company systems are encrypted, for example in a printed copy or a separate archive.
Test to know
NIST SP 800-84 distinguishes three activities: train the staff, exercise the plans, test the systems. The tabletop exercise is a discussion exercise in which a facilitator presents a scenario and asks the participants questions, who explain what they would do. [31] It costs little, takes a morning and surfaces gaps no document reveals: the wrong on-call number, the supplier who does not have the datacentre key, the administrator who does not know who can authorize stopping the line.
| Test | Objective | Frequency |
|---|---|---|
| Sample file restore | Verify integrity and readability of backups | Monthly |
| Full ERP restore in an isolated environment | Measure real recovery time and point against RTO and RPO | Half-yearly |
| Ransomware tabletop with management | Rehearse decisions, communication and assessment of notifications | Annual |
| Degraded-mode test | Work half a day without the ERP in one department | Annual |
| On-call chain test | Reach all roles out of hours through alternative channels | Quarterly |
Every test ends with minutes comparing the results with the objectives, as continuity-management systems under ISO 22301 also require. [37] If restoring the ERP took fourteen hours against an RTO of eight, the plan did not fail: it did its job, showing a problem before an attack did. At that point one decides whether to invest to cut the time or to revise, with management, the objective.
- Write the crisis plan, BCP and DRP starting from the BIA and the dependency matrix.
- Prepare recovery runbooks accessible even without the company systems.
- Prepare template messages for employees, customers and suppliers.
- Run the test programme and record real times, problems and actions.
- Update the plans after every test, incident or change.
- Documents
- Crisis-management plan; BCP; DRP; runbooks; minutes of restore tests and exercises; process-owner sign-off.
- Who
- BCM manager (R), IT and suppliers (R for DR), process owners (testing), management (A).
- References
- Leg. Decree 138/2024 art. 24(c); GDPR art. 32(1)(c); NIST SP 800-34 and 800-84; ISO 22301.
Training and culture
Policies no one understands protect no one. Training works when it is different for each role, short, repeated and measured by behaviours instead of attendance.
NIS2 asks two distinct things: that members of the governing bodies follow training to be able to assess risks and their impact, and that the organization adopt cyber-hygiene and training practices for staff. [2] The AI Act adds AI literacy for those who use these systems. [21]
| Audience | Content | Format |
|---|---|---|
| Directors and management | NIS2 responsibilities, reading the risk register, decisions in a crisis, notifications | Annual session and tabletop |
| All staff | Phishing, passwords and MFA, reporting anomalies, correct use of AI, personal data | Short quarterly modules, simulations |
| Administration and procurement | Payment fraud, IBAN change, fake CEO including synthetic voice or video, checks on an independent channel | Workshop with real cases |
| IT and system administrators | Hardening, privilege management, evidence collection, recovery procedures | Technical training and exercises |
| Developers | Secure development, OWASP, secrets and dependency management, CRA obligations | Annual specialist training |
| Production | USB sticks, maintainer access, reporting anomalous machine behaviour | Shop-floor briefings |
Phishing simulations are useful if they serve to learn, not to punish. Whoever clicks receives an explanation at once; above all one measures how many people report the message, because rapid reporting is what lets the SOC block a campaign before it hits others. The way simulations are run must be communicated transparently, consistently with the rules on monitoring of workers.
- Define the annual plan by role, including directors' training and AI literacy.
- Integrate security into the onboarding of new hires and into role changes.
- Plan simulations for training purposes with immediate feedback messages.
- Measure reporting rate, completion and test results.
- Keep registers and materials as evidence.
- Documents
- Training plan; attendance and completion register; simulation results; signed acceptable-use policy.
- Who
- HR (R), CISO (A), department heads (C), management (audience and sponsor).
- References
- Leg. Decree 138/2024 arts. 23 and 24(g); AI Act art. 4; ENISA, SME guide.
Internal audit, measurement and review
The last phase reopens the first. Management receives the results, decides what to change and approves the next year's plan. Without this step the programme stops at the first wave of enthusiasm.
Measure what matters
NIS2 requires procedures to assess the effectiveness of risk-management measures, and the GDPR a procedure to regularly test and verify them. [2] [10] A useful indicator has a precise definition, a known denominator, a verifiable source and an approved threshold.
| Indicator | Definition | Source |
|---|---|---|
| Privileged MFA coverage | Administrative accounts with phishing-resistant MFA / total administrative accounts | Directory export |
| EDR coverage | Endpoints with active EDR / endpoints in the inventory | EDR console and asset register |
| Overdue KEV vulnerabilities | Vulnerabilities in the KEV catalogue not fixed within the internal term | VA report |
| Recovery against RTO | Time measured in the last test / approved RTO, for each critical service | Test minutes |
| Phishing reporting rate | Users who report the simulation / recipient users | Simulation platform |
| Findings open past deadline | Audit and pentest findings not closed by the expected date | Findings register |
The internal audit
Once a year someone who did not build the controls verifies that they exist and work. It can be an external consultant or an internal person from another function, as long as independent. The guidelines for conducting management-system audits are those of ISO 19011, published in its new 2026 edition with greater attention to risk analysis. [38] The auditor defines criteria and sample, interviews, observes, examines registers and configurations, and classifies findings into non-conformities, observations and improvement opportunities. Every non-conformity receives a root-cause analysis and a corrective action with a deadline.
The management review
The review is the meeting where the cycle closes. On the table: status of the previous review's actions, changes in context and rules, indicators, results of audits and checks, incidents, updated risks, restore-test results, investment proposals. Out come written decisions: new priorities, budget, accepted risks, objectives for the new year. For a NIS entity the review minutes are also the most direct proof that the directors have overseen, as the law requires.
- Define indicators, thresholds and reporting cadence.
- Plan and run the annual internal audit with independent auditors.
- Manage non-conformities with root-cause analysis and corrective actions.
- Convene the management review and record the decisions.
- Update the register of obligations, risks, plans and roadmap for the next cycle.
- Documents
- Indicators register; audit programme and report; register of non-conformities and corrective actions; review minutes; next annual plan.
- Who
- Auditor (R for the audit), CISO and GRC (R for reporting), management (A).
- References
- Leg. Decree 138/2024 arts. 23 and 24(f); GDPR art. 32(1)(d); ISO/IEC 27001 clauses 9-10; ISO 19011:2026.
The twelve-month calendar
The phases are not run one after another: they overlap, and some never end. ALFA's calendar shows how a realistic programme spreads over a year, anchored to the external deadlines that cannot be moved.
In the simulation ALFA registered on the ACN platform in the early-2026 window and received in spring the notice of inclusion among the important entities. The programme starts in October 2026. The external deadlines below are those indicated for entities included in 2026 and for product manufacturers; every real company must recompute them against its own notices. [6] [7] [19] [25]
| Phase | Oct | Nov | Dec | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mandate, rules and roles (1-3) | activity in October 2026 | activity in November 2026 | ||||||||||
| Inventory (4) | activity in October 2026 | activity in November 2026 | activity in December 2026 | |||||||||
| BIA and risk (5-6) | activity in November 2026 | activity in December 2026 | activity in January 2027 | |||||||||
| Gap analysis and pentest (7-8) | activity in December 2026 | activity in January 2027 | ||||||||||
| Quick remediation (9) | activity in November 2026 | activity in December 2026 | activity in January 2027 | |||||||||
| Technical controls (10) | activity in January 2027 | activity in February 2027 | activity in March 2027 | activity in April 2027 | activity in May 2027 | activity in June 2027 | ||||||
| Secure development and CRA (11) | activity in December 2026 | activity in January 2027 | activity in February 2027 | activity in March 2027 | activity in April 2027 | activity in May 2027 | activity in June 2027 | activity in July 2027 | activity in August 2027 | activity in September 2027 | ||
| Suppliers (12) | activity in February 2027 | activity in March 2027 | activity in April 2027 | activity in May 2027 | ||||||||
| SOC and monitoring (13) | activity in March 2027 | activity in April 2027 | activity in May 2027 | activity in June 2027 | ||||||||
| Incident response (14) | activity in December 2026 | activity in January 2027 | ||||||||||
| BCP, DR and tests (15) | activity in March 2027 | activity in April 2027 | activity in May 2027 | activity in June 2027 | activity in July 2027 | |||||||
| Training (16) | activity in November 2026 | activity in February 2027 | activity in May 2027 | activity in August 2027 | ||||||||
| Internal audit and review (17) | activity in August 2027 | activity in September 2027 |
| Date | Obligation | Source |
|---|---|---|
| Already in force | CRA reporting of exploited vulnerabilities and severe product incidents (from 11 September 2026) | Reg. (EU) 2024/2847 [18] |
| 31 December 2026 | Designation of the CSIRT contact (entities included in 2026) | ACN Det. 2026 [6] |
| 1 January 2027 | Start of the obligation to notify significant incidents (entities included in 2026) | ACN Det. 2026 [6] |
| 1 January - 28 February 2027 | Annual registration or update on the ACN platform | Leg. Decree 138/2024 art. 7 [2] |
| 20 January 2027 | Application of the Machinery Regulation | Reg. (EU) 2023/1230 [25] |
| 15 April - 31 May 2027 | Update of information on the ACN platform and communication of relevant suppliers | Leg. Decree 138/2024 art. 7; ACN Det. [7] |
| 31 July 2027 | Adoption of the baseline security measures (entities included in 2026) | ACN Det. 2026 [6] |
| 2 December 2027 | AI Act obligations for the high-risk systems of Annex III | Reg. (EU) 2026/1744 [21] |
| 11 December 2027 | Full application of the Cyber Resilience Act | Reg. (EU) 2024/2847 [19] |
The order has a precise logic. The quick remediation actions start at once, before the analysis is even complete, because orphan accounts and MFA-less access are obvious risks that need no matrix to be recognized. The incident-response procedure is written by December because from 1 January a significant incident must be notified. The longer projects, such as segmentation, SOC and restore tests, close before the July deadline for the baseline measures, leaving the summer for the internal audit and the review.
The documentation file
In security a simple rule holds: what is not documented, for an auditor, an authority or a customer, does not exist. The file gathers in one place the documents that prove each phase, with an owner and an update cadence.
No expensive software is needed: a shared folder with controlled permissions, a structure that mirrors the phases, file names with version and date, and an index. Discipline matters more: every document has an owner, an approval date and a next-review date. A copy of the file, at least of the crisis, continuity and recovery plans and the contacts, must stay accessible even if the company systems are unavailable.
| # | Document | Phase | Owner | Update |
|---|---|---|---|---|
| Govern | ||||
| 1 | Kick-off resolution and board minutes | 1 | Management | At every decision |
| 2 | Programme Project Charter | 1 | CISO | Annual |
| 3 | Risk-appetite statement | 1, 6 | Management | Annual |
| 4 | Appointment letters (CISO, point of contact, deputy, CSIRT contact, backups) | 3 | Management | At every change |
| 5 | Security org chart and RACI matrix | 3 | CISO | Annual |
| 6 | General security policy | 3 | CISO | Annual |
| 7 | Register of policies and procedures | 3 | GRC | Continuous |
| 8 | Decisions register and security-committee minutes | 3 | CISO | Monthly |
| 9 | Register of obligations and reasoned applicability matrix | 2 | Legal | Annual and at every change |
| 10 | ACN registration receipts and notices | 2 | Point of contact | Annual |
| 11 | Compliance calendar | 2 | GRC | Continuous |
| 12 | Records of processing activities | 2, 4 | Privacy contact | At every new processing |
| 13 | Impact assessments (DPIA) | 2, 13 | Privacy contact | At every relevant change |
| 14 | Union agreement or INL authorization and employee notices | 13 | HR | At every new tool |
| 15 | Part of the 231 model on cybercrimes | 2 | Legal, SB | Annual |
| Know and measure | ||||
| 16 | Asset register | 4 | IT | Continuous |
| 17 | Software, SaaS and cloud inventory | 4 | IT | Continuous |
| 18 | Register of privileged identities and service accounts | 4, 10 | IT | Quarterly |
| 19 | Network diagram, including OT zones and remote access | 4 | Network engineer | At every change |
| 20 | Data-flow diagram | 4 | Privacy contact, IT | Annual |
| 21 | BIA report and approved MTD, RTO, RPO table | 5 | BCM | Annual |
| 22 | Risk-management methodology | 6 | Risk manager | Biennial |
| 23 | Risk register | 6 | Risk manager | Quarterly |
| 24 | Risk-treatment plan | 6 | CISO | Quarterly |
| 25 | Formal residual-risk acceptances | 6 | Management | At expiry |
| 26 | Gap-analysis report, current and target profile | 7 | GRC | Annual |
| 27 | Test authorizations and rules of engagement | 8 | CISO | Per test |
| 28 | VA, penetration-test and retest reports | 8 | CISO | Per test |
| Protect | ||||
| 29 | Remediation backlog and approved roadmap | 9 | CISO | Monthly |
| 30 | Change register | 9 | IT | Continuous |
| 31 | Register of exceptions and compensating controls | 9 | CISO | At expiry |
| 32 | Configuration baseline | 10 | Security engineer | Annual |
| 33 | Access-control and authentication policy | 10 | CISO | Annual |
| 34 | Cryptographic policy | 10 | Security engineer | Annual |
| 35 | Backup policy and restore-test register | 10, 15 | IT | Annual / monthly |
| 36 | Secure development procedure and SBOM per version | 11 | DevSecOps | Per release |
| 37 | Vulnerability-disclosure policy and CRA reporting procedure | 11 | Engineering | Annual |
| 38 | AI use policy | 11, 16 | CISO, legal | Annual |
| 39 | Supplier policy, classified register and assessments | 12 | Procurement | Annual |
| 40 | Contracts with security clauses and art. 28 GDPR agreements | 12 | Legal | Per contract |
| 41 | Supplier remote-access register | 12 | IT | Continuous |
| Detect, respond, recover | ||||
| 42 | Logging policy and use-case catalogue | 13 | CISO | Half-yearly |
| 43 | SOC contract with service levels | 13 | Procurement, CISO | Annual |
| 44 | Incident-response plan and playbooks | 14 | Incident manager | Annual and after incidents |
| 45 | Notification matrix and pre-filled forms | 14 | Legal | Annual |
| 46 | Incident register and data-breach register | 14 | Incident manager, privacy contact | Continuous |
| 47 | Post-incident reports and lessons learned | 14 | CISO | Per incident |
| 48 | Crisis-management plan and template messages | 15 | Management, communication | Annual |
| 49 | Business continuity plan | 15 | BCM | Annual |
| 50 | Disaster recovery plan and runbooks | 15 | IT | Annual and after tests |
| 51 | Minutes of tests and exercises | 15 | BCM | Per test |
| Improve | ||||
| 52 | Training plan and completion registers | 16 | HR | Annual |
| 53 | Indicators register, internal-audit report, non-conformities and corrective actions | 17 | GRC, auditor | Quarterly / annual |
| 54 | Management-review minutes | 17 | Management | Annual |
A mature security programme is recognized not by the absence of incidents, but by the ability to demonstrate, at any moment, what it decided, why and with what result.
Having arrived here, the path returns to its starting point. The management review has just approved the second year's priorities: certify the management system, extend monitoring to the production network, complete the machines' CRA compliance. It is the sign that the programme has stopped being a project and has become the way the company works.
Documentary apparatus
Sources, method and limits
Sources consulted and verified between 16 and 18 October 2026. Where the official page was unreachable, the secondary source used is indicated and the datum is flagged as to be re-checked before any compliance step.
European and national law
- Directive (EU) 2022/2555 (NIS2), consolidated textArts. 2-3 scope and categories, art. 20 governance, art. 21 measures, art. 23 notifications, art. 34 penalties, annexes I and II.
- Legislative Decree 4 September 2024, no. 138 (Normattiva)In force from 16 October 2024. Art. 7 registration and point of contact, art. 23 governing bodies, art. 24 measures (points a-l), art. 25 notification, art. 38 penalties.
- ACN, NIS portalRegistration platform, determinations and guidelines. Unreachable from the verification tools during drafting: ACN content was checked via sources 4-7.
- Assolombarda, ACN Determinations 379887 and 379907 (9 January 2026)Secondary source. Det. 379907/2025 replaces 164179/2025 from 15 January 2026; number of measures and requirements for important and essential entities.
- ACN, NIS guidelines: reading guide to the baseline specifications (September 2025)Copy of the ACN document hosted by dirittobancario.it. Use of the 2025 National Framework, measure coding, baseline significant incidents.
- PMI.it, NIS2: new obligations and deadlines (ACN Det. 127434/2026)Secondary source. Deadlines for entities included in 2026: CSIRT contact, notification from 1 January 2027, measures by 31 July 2027. To be re-checked on the ACN portal.
- Cyberness, Relevant suppliers: ACN Determination 127437/2026Secondary source. Communication of relevant suppliers in the 15 April - 31 May window.
- European Commission, NIS2 DirectiveTargeted amendment proposals of 20 January 2026 together with the new Cybersecurity Act; not adopted as of October 2026.
- Implementing Regulation (EU) 2024/2690Technical requirements for digital-service providers (DNS, cloud, data centres, managed services and others).
- Regulation (EU) 2016/679 (GDPR)Arts. 5, 24, 25, 28, 30, 32-35, 37, 83.
- Garante, Records of processing activitiesLimits of the exemption for enterprises with fewer than 250 employees.
- Garante, Personal-data breaches (data breach)Online notification procedure and self-assessment tool.
- EDPB, Guidelines 9/2022 on breach notification (v. 2.0, 28 March 2023)
- Garante, measure 6 June 2024 no. 364: guidance document on email metadataIndicative retention not exceeding 21 days; art. 4 Law 300/1970 guarantees for longer retention; DPIA.
- National Labour Inspectorate, authorization request under art. 4 Law 300/1970Permitted purposes, agreement with worker representatives or authorization, notice under para. 3. Text of the rule: Law 20 May 1970 no. 300, art. 4.
- Law 28 June 2024, no. 90 (Official Gazette no. 153 of 2 July 2024)Strengthening national cybersecurity and cybercrimes: notification obligations (art. 1), amendments to the penal code (art. 16) and to art. 24-bis of Leg. Decree 231/2001 (art. 20).
- Garante and ACN, Guidelines on cryptographic functions: password storage (measure 7 December 2023 no. 594)
- European Commission, Cyber Resilience Act: reporting obligationsFrom 11 September 2026; 24 h, 72 h, final report at 14 days or one month; recipients.
- European Commission, Cyber Resilience Act implementation (Reg. EU 2024/2847)Calendar: 11 June 2026, 11 September 2026, 11 December 2027.
- ENISA, CRA Single Reporting Platform: FAQPlatform operational from 11 September 2026.
- Regulation (EU) 2026/1744, amending the AI Act (Digital Omnibus on AI)In force from 27 July 2026. New high-risk dates; new text of art. 4 on literacy; SME measures.
- European Commission, regulatory framework on AI (Reg. EU 2024/1689)Application calendar and 2026 amendments.
- Law 23 September 2025, no. 132, provisions on artificial intelligenceIn force from 10 October 2025; art. 11 on the use of AI at work.
- ESMA, Digital Operational Resilience Act (Reg. EU 2022/2554)Application from 17 January 2025 to financial entities.
- EU-OSHA, Regulation (EU) 2023/1230 on machineryApplication from 20 January 2027; Annex III requirements, points 1.1.9 and 1.2.1.
- Directive (EU) 2022/2557 (CER)Cited in the text as [54]. Transposed by Leg. Decree 4 September 2024 no. 134; applies to entities identified as critical.
Standards, frameworks and technical guides
- NIST, Cybersecurity Framework 2.0 (CSWP 29, 26 February 2024)Six functions, current and target profiles, implementation tiers.
- NIST SP 1300, CSF 2.0 Small Business Quick-Start Guide
- NIST SP 800-30 Rev. 1, Guide for Conducting Risk Assessments
- NIST SP 800-34 Rev. 1, Contingency Planning GuideDefinitions of MTD, RTO, RPO; three steps of the BIA.
- NIST SP 800-61 Rev. 3 (April 2025), Incident Response Recommendations
- NIST SP 800-84, Guide to Test, Training, and Exercise Programs
- NIST SP 800-115, Technical Guide to Information Security Testing and Assessment
- NIST SP 800-63B-4 (July 2025), Authentication and Authenticator Management
- NIST SP 800-82 Rev. 3, Guide to Operational Technology SecurityUnder revision in 2026.
- NIST SP 800-218, Secure Software Development Framework v1.1Version 1.2 was in draft as of October 2026.
- ISO/IEC 27001:2022, Information security management systemsWith Amd 1:2024. Full text paid at ISO and UNI.
- ISO 22301:2019, Business continuity management systemsUnder revision.
- ISO/TC 176, publication of ISO 19011:2026
- CIS Controls v8.1, Implementation Group 156 essential cyber-hygiene safeguards.
- FIRST, Exploit Prediction Scoring System (EPSS)Version 5 published from 15 June 2026.
- FIRST, CVSS v4.0 Specification
- CISA and partners, #StopRansomware GuideOffline, encrypted backups, periodic availability and integrity tests.
- CISA, Implementing Phishing-Resistant MFA
- CISA, Back Up Business DataThe 3-2-1 rule.
- ENISA, Cybersecurity guide for SMEs: 12 steps to securing your business
- ENISA Threat Landscape 2026 (22 September 2026)
- MITRE ATT&CK, versionsVersion 20.0 of 13 October 2026.
- OWASP Application Security Verification Standard 5.0
- OWASP Top 10:2025
- National Framework for Cybersecurity and Data Protection, 2025 EditionCIS Sapienza and CINI with ACN support; core aligned with NIST CSF 2.0.
- ENISA, European Cybersecurity Skills Framework (ECSF)
- NIST, NICE Workforce Framework for Cybersecurity
- No More Ransom (Europol, Dutch police and partners)
- CISA, Known Exploited Vulnerabilities Catalog
- IEC, Understanding IEC 62443Series of standards for the security of industrial automation and control systems.
- ISO/IEC 27035-1:2023, Information security incident management: Principles and process
- OWASP Top 10 for LLM Applications 2025
Method and limits. ALFA S.r.l. is an invented company: size, systems, BIA and risk values, test results and the incident timeline are teaching examples, not measured data. The rules are cited in the text in force as of October 2026; the 2026 ACN determinations were verified via secondary sources because the Agency's portal was not consultable by the verification tools, and they must be re-checked before any compliance step. European legislative proposals still under discussion are indicated as such. The role descriptions are functions, not contractual profiles; the professional certifications cited are examples common on the market, not legal requirements. This guide is not legal advice: the applicability of each rule to a specific company must be confirmed with a professional.